Pencari kesalahan kabel
>
Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables

Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables

Rincian produk:
Tempat asal: Xi'an
Nama merek: XZH TEST
Sertifikasi: CE
Nomor model: XHFZ510-B2
Informasi Rinci
Tempat asal:
Xi'an
Nama merek:
XZH TEST
Sertifikasi:
CE
Nomor model:
XHFZ510-B2
Metode pembumian:
Tempat kerja, tempat uji coba
Waktu kerja yang berkelanjutan:
≥8 jam
Suhu Sekitar:
-40 ℃ hingga +80 ℃
Menyoroti:

High Light

Menyoroti:

Precision Cable Fault Simulation Device

,

Reliable Cable Fault Locator

,

Simulate All Types of Faults Power Cable Tester

Trading Information
Kuantitas min Order:
1set
Kemasan rincian:
Kemasan kayu
Waktu pengiriman:
5-8 hari kerja
Syarat-syarat pembayaran:
T/T
Menyediakan kemampuan:
3000unit/tahun
Deskripsi Produk
XHFZ510-B2
Urbanization and rising electricity demand promote the replacement of overhead lines with cables. Training for cable fault detection personnel is a persistent challenge. Our self-developed electrical test simulation training system, built on decades of expertise, simulates all cable faults to support seamless training.
Technical Parameters
High-voltage cable length ≥300 meters (coaxial cable)
High-voltage cable outer diameter ≥φ12mm
High-voltage cable main insulation withstand voltage ≥30kVDC
High-voltage cable outer sheath withstand voltage ≥5kVDC
Number of high-voltage cable faults ≥4, with ≥1 fault at a T-joint


Panel Introduction


Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables 0

Test Terminals:

1) Fault Phase: Connection port for the fault phase during high-voltage bridge fault testing;

2) Reference Phase: Connection port for the reference phase during high-voltage bridge fault testing;

3) Test Ground: Connection port for the test ground during high-voltage bridge fault testing;

4) Fault Point Proportion: Adjustment knob for the fault point proportion during high-voltage bridge fault testing;

5) Main Insulation: Connection port for the cable core when the cable fault tester tests for main insulation faults;

6) Test Ground: Connection port for the cable shielding layer when the cable fault tester tests for main insulation faults;

7) Grounding Post: Instrument grounding point for safety protection.

Precision and Reliability Cable Fault Simulation Device for Simulating All Types of Faults in Power Cables 1